Journal Papers
2005
Bertram, C.D. and Nugent, A.H. (2005) The flow field downstream of an oscillating collapsed tube. ASME Journal of Biomechanical Engineering 127(1), 39-45, DOI 10.1115/1.1835351.
Bertram, C.D. (2005) Measurement for implantable rotary blood pumps (review). Physiological Measurement 26(4), R99-R117, DOI 10.1088/0967-3334/26/4/R01.
Marzo, A., Luo, X.Y. and Bertram, C.D. (2005) Three-dimensional collapse and steady flow in thick-walled flexible tubes. Journal of Fluids & Structures 20(6), 817-835, DOI 10.1016/j.fluidstructs.2005.03.008.
Arslan, N., Loth, F., Bertram, C.D. and Bassiouny, H.S. (2005) Transitional flow field characterization inside an arteriovenous graft-to-vein anastomosis under pulsatile flow conditions. European Journal of Mechanics B, Fluids 24(3), 353-365, DOI 10.1016/j.euromechflu.2004.09.004.
Bertram, C.D., Brodbelt A.R. and Stoodley, M.A. (2005) The origins of syringomyelia: numerical models of fluid/structure interactions in the spinal cord. ASME Journal of Biomechanical Engineering 127(7), 1099-1109, DOI 10.1115/1.2073607.
Bertram, C.D. and Gaver, D.P. III (2005) Position paper: biofluid mechanics of the pulmonary system. Annals of Biomedical Engineering 33(12), 1681-1688, DOI 10.1007/s10439-005-8758-0.
2006
Bertram, C.D. and Tscherry, J. (2006) The onset of flow-rate limitation and flow-induced oscillations in collapsible tubes. Journal of Fluids & Structures 22(8), 1029-1045, DOI 10.1016/j.jfluidstructs.2006.07.005.
2007
Wang, W., Bertram, C.D. and Wiley, D.E. (2007) Effects of collapsible-tube-induced pulsation vigour on membrane filtration performance. Journal of Membrane Science 288(1-2), 298-306, DOI 10.1016/j.memsci.2006.11.028.
2008
Jones, I., Ricciardi, L., Hall, L., Hansen, H., Varadan, V., Bertram, C., Maddocks, S., Enderling, S., Saint, D., Al-Sarawi, S. and Abbott, D. (2008) Wireless RF communication in biomedical applications. Smart Materials & Structures 17(1), 015050 (10 pp.), DOI 10.1088/0964-1726/17/1/015050.
Bertram, C.D., Bilston L.E. and Stoodley, M.A. (2008) Tensile radial stress in the spinal cord related to arachnoiditis or tethering: a numerical model. Medical & Biological Engineering & Computing 46(7), 701-707, DOI 10.1007/s11517-008-0332-0.
Holmes, R.L., Burford, R.P. and Bertram, C.D. (2008) Preparation and characterization of poly methyl methacrylate beads. Journal of Applied Polymer Science 109(3), 1814-1822, DOI 10.1002/app.28216.
Nugent, A.H. and Bertram, C.D. (2008) Measurement and analysis of the flow field in a pulsatile ventricular assist device. Proc. IMechE Part H, Journal of Engineering in Medicine 222(4), 563-571, DOI 10.1243/09544119JEIM293.
Bertram, C.D. (2008) Flow-induced oscillation of collapsed tubes and airway structures. Respiratory Physiology & Neurobiology (invited review, publ. on-line 26.4.2008), DOI 10.1016/j.resp.2008.04.011.

